Brand Name : BRITEC
Model Number : BR-25GR 4P
Certification : TUV/CE/CB/ISO9001
Place of Origin : China
MOQ : 1 Piece/Pieces
Payment Terms : L/C, D/A, T/T, Western Union
Supply Ability : 50000 Piece/Pieces Month
Delivery Time : Shipped in 15 days after payment
Packaging Details : EXPORT PACKING
Item Name : thunder protector
Type : T1+T2
Pole : 4P
In : 25kA
Backup fuse : 315 A gG
Nominal discharge current : 25kA
MOQ : 2PCS
Waveform : 10/350
4P class I Surge Protection Device low voltage surge arrestor SPD
BRITEC is a real AC&DC surge protection device (SPD) manufacturer, also provide OEM/ODM service. some of the products approved by TUV, CB, CE, EAC according to IEC 61643-11:2011 and EN 61643-11:2012.
T1, Class B, Class I, Iimp(10/350μs): 25kA/50kA
T1+T2, Class B+C, Class I+II, Iimp(10/350μs): 12.5kA/25kA
T2, Class C, Class II, Imax(8/20μs): 20/40/80/100/120/200kA
T3, Class D, Class III, Uoc(1.2/50μs): 10kV, In(8/20μs): 5kA, Imax(8/20μs): 10kA
low voltage surge arrestor Technology characteristic:
Specification | BR-25GR 4P |
Item name | Surge Arrester |
SPD dassification according to EN61643-11 | Type 1 + Type 2 |
SPD dassification according to EN61643-11 | Class I + Class II |
Max continuous 0perating a.c. voltage Uc | 275V |
Lightning impulse current (10/350µs) limp | 25kA |
Norminal discharge current (8/20µs) In | 25kA |
Maximum discharge current (8/20µs) Imax | 100kA |
Voltage protection level Up | ≤1.8kV |
Follow current extinguishing capability a.c. lifi | 5kA rms |
Max. backup fuse | 315A gG |
Response time tA | ≤100ns |
Operating temperature range Tu | -40℃—80℃ |
Cross-section area (Min.) | 4mm2 |
Cross-section area (Max.) | 35mm2 |
For mounting on | 35mm Din rail |
Enclosure material | Thermoplastic UL94-V0 |
Degree of protection | IP20 |
Main benefits (25GR)
The impulse current of 25kA per pole (10/350 µs wave) satisfies all requirements for overvoltage surge protection
Q1: Selection of surge protector
Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of EN 61643-11 / IEC 61643-11 is 25 ka (10/350), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.
Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?
A2: We are a lightning surge protectors manufacturer.
Q3: Warranty and services:
A3:1. Warranty 5 years
2. lightning surge protectors products and accessories have been tested 3 times before ship out.
3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.
Q4: How can I get some lightning surge protectors samples?
A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.
Q5: Is the sample available and free?
AS: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.
Q6: Do you accept customized order?
A6: Yes, we do.
Q7: What’s the delivery time?
A7: It usually takes 7-15days after confirming payment, but a specific time should be based on the order quantity.
![]() |
BR-25GR 4P Class I type 1 Surge Surge Arrestor SPD Thunder Protector spark gap spd type1 4p surge protector Images |